Wednesday, February 08, 2012

Electromagentic Industries FTP Server Access

Here you will be able to download files from our FTP server.  Click here for FTP access.

 

                                                                                             ELECTROMAGNETIC INDUSTRIES LLP
                                                  1507 Beaumont Street, Baytown, TX 77520 | Phone: (281) 422-5225 | Fax: (281) 422-5275

 0

Last Update:8/1/2011

,

Ground Fault Relay: Industrial Ground Fault Relay, Industrial Ground Fault Protection, The BGFL Class 1 Ground Fault Relay Manufactured by Electromagnetic Industries LLP meets NEC service entrance equipment standards. The BGFL Operates with molded case power circuit breakers, bolted pressure switches, or fusible disconnect switches. The BGFL, has an Electro-mechanical relay output positive “ON” and “OFF”. The BGFL has two styles, “Standard” (without interlock) and “Zone Interlocking”, Integral test panel with “Push to Test” and “Shunt Trip Bypass” pushbuttons for proper testing of device with the ability to trip or not trip the protective device. It also has a visual trip indicator, adjustable time delay, discrete current threshold adjustment.   The BGFL Ground Fault Relay Manufactured by Electromagnetic Industries LLP along with the accompanied sensor are used together to provide a system for detecting ground fault current in a grounded AC power System. When the system detects a fault, of a preselected (adjustable) level for the duration of a preselected (adjustable) time delay, the relay initiates a trip of the Shunt Trip Device to open the contacts/breaker and clear the Ground Fault. The Electromagnetic Industries BGFL Ground Fault Relay has current trip set points of 5 – 60Amps, 30 – 360 Amps and 100 to 1200 Amps. The BGFL is UL Listed. Models include: BGFL 159, BGFL 259, BGFL 137, BGFL 147, BGFL 157, BGFL 139, BGFL 149, BGFL 237, BGFL, 247, BGFL 257, BGFL 239, BGFL 249.GFL 041X , GFL 051X , GFL 058X, GFL 080X ,GFL 101X , Ground Fault Sensors. The GFL Ground Fault Sensor manufactured by Electromagnetic Industries LLP is used with the BGFL and GFP Ground Fault Relays to provide a way to detect and protect from Ground Fault Conditions in Grounded AC power systems. GFP Ground Fault Relay: Industrial Ground Fault Relay, Industrial Ground Fault Protection, Industrial Ground Fault Indicator The GFP Ground Fault Relay Manufactured by Electromagnetic Industries LLP is a Class 1 relay that meets NEC service entrance equipment standards. The GFP Operates with molded case power circuit breakers, bolted pressure switches, or fusible disconnect switches. The GFP, has an Electro-mechanical relay output positive “ON” and “OFF” and has two styles, “Standard” (without interlock) and “Zone Interlocking”, Integral test panel with “Push to Test” and “Shunt Trip Bypass” pushbuttons for proper testing of device with the ability to trip or not trip the protective device. It also has a visual trip indicator, real time Ground Fault level display, adjustable time delay, discrete current threshold adjustment. The GFP also retains the information of what the Ground Fault level was at trip/power down. The GFP has three time delay curves. One that requires the fault to exist for the entire time delay and two different curves for Inverse Time Delay settings. The GFP Ground Fault Relay Manufactured by Electromagnetic Industries LLP along with the accompanied sensors are used to provide a system for detecting ground fault current in a grounded AC power System. When the system detects a fault it will display the level and at an adjustable preselected level for the duration of an adjustable preselected time delay, the relay initiates a trip of the Shunt Trip Device to open the contacts/breaker and clear the Ground Fault. The Electromagnetic Industries GFP Ground Fault Relay has current trip set points of 5 – 60Amps, 30 – 360 Amps and 100 to 1200 Amps. The GFP is UL Listed.  GFP 111, GFP 112, GFP 113, GFP 121, GFP 122, GFP 123, GFP 131, GFP 132, GFP 133, GFP 141, GFP 142, GFP 143, GFP 211, GFP 212, GFP 213, GFP 222, GFP 223, GFP 231, GFP 232, GFP 233, GFP 241, GFP 242, GFP 243.  GFM Ground Fault Relays and Sensors: GFM 252, GFM 262, GFM 353, GFM 363, GFM 425, GFM 453, GFM 363B, GFM 375D. The GFM manufactured be Electromagnetic Industries is a (Class 1) Ground Fault protection system used to minimize damage to equipment due to arcing ground faults. The GFM system is designed for all poly-phase applications and is ideal for motor control, motor control centers and high voltage starters The GFM relay comes in 3 Model/Series. GFM 200, GFM 300 and GFM 400 Capacitor Trip Device: CTD 1, CTD 2, CTD 3, CTD 4, CTD 5, CTD 4-120, CTD 4-240, CTD 5-120, CTD 5-240  The CTD-1 manufactured by Electromagnetic Industries is designed to provide a source of energy for a circuit breaker or switch to trip during a loss of normal AC or DC power. These devices are protected against inadvertent short circuits, input from line surges and inductive kickback from trip coils. The nominal 120Volts AC or 125 DC is applied between “AC” and "COM” terminals. This voltage is half wave rectified and applied across the trip capacitor to give the output trip voltage. The charge stored in the capacitor (330 uF @168 VDC) is available between the positive and “COM” terminals for the trip coil operation. The half wave rectification circuitry provides the advantage of maintaining a common neutral connection from the input and output while still maintaining the charge in the trip capacitor after a loss of control power. The capacitor is continuously charged when control power is applied. This provides energy for normal trip coil operation. Because mechanical relays are not used, energy from the trip coil operation is immediately available with the loss of control power. When the control power returns, the capacitor will recharge and will be able to supply energy for the next trip coil operation.  The CTD-2 manufactured by Electromagnetic Industries is designed to provide a source of energy for a circuit breaker or switch to trip during a loss of normal AC or DC power. These devices are protected against inadvertent short circuits, input from line surges and inductive kickback from trip coils. The nominal 120Volts AC or 125 DC is applied between “AC” and ‘COM” terminals. This voltage is half wave rectified and applied across the trip capacitor to give the output trip voltage. The charge stored in the capacitor (1500 uF @ 168 VDC) is available between the positive and “COM” terminals for the trip coil operation. The half wave rectification circuitry provides the advantage of maintaining a common neutral connection from the input and output while still maintaining the charge in the trip capacitor after a loss of control power. The capacitor is continuously charged when control power is applied. This provides energy for normal trip coil operation. Because mechanical relays are not used, energy from the trip coil operation is immediately available with the loss of control power. When the control power returns, the capacitor will recharge and will be able to supply energy for the next trip coil operation. The CTD-3 manufactured by Electromagnetic Industries is designed to provide a source of energy for a circuit breaker or switch to trip during a loss of normal AC or DC power. These devices are protected against inadvertent short circuits, input from line surges and inductive kickback from trip coils. The nominal 240Volts AC is applied between “AC” and ‘COM” terminals. This voltage is half wave rectified and applied across the trip capacitor to give the output trip voltage. The charge stored in the capacitor (330 uF @ 338 VDC) is available between the positive and “COM” terminals for the trip coil operation. The half wave rectification circuitry provides the advantage of maintaining a common neutral connection from the input and output while still maintaining the charge in the trip capacitor after a loss of control power. The capacitor is continuously charged when control power is applied. This provides energy for normal trip coil operation. Because mechanical relays are not used, energy from the trip coil operation is immediately available with the loss of control power. When the control power returns, the capacitor will recharge and will be able to supply energy for the next trip coil operation.  The CTD 4-120 manufactured by Electromagnetic Industries is designed to provide a source of energy for a circuit breaker or switch to trip during a loss of normal AC or DC power. These devices are protected against inadvertent short circuits, input from line surges and inductive kickback from trip coils. The nominal 120Volts AC is applied between “AC” and ‘COM” terminals. The charge stored in the capacitor (4500 uF @ 168 VDC) is available between the positive and “COM” terminals for the trip coil operation. The half wave rectification circuitry provides the advantage of maintaining a common neutral connection from the input and output while still maintaining the charge in the trip capacitor after a loss of control power. The capacitor is continuously charged when control power is applied. This provides energy for normal trip coil operation. Because mechanical relays are not used, energy from the trip coil operation is immediately available with the loss of control power. When the control power returns, the capacitor will recharge and will be able to supply energy for the next trip coil operation.  The CTD 4-240 manufactured by Electromagnetic Industries is designed to provide a source of energy for a circuit breaker or switch to trip during a loss of normal AC or DC power. These devices are protected against inadvertent short circuits, input from line surges and inductive kickback from trip coils. The nominal 240Volts AC is applied between “AC” and ‘COM” terminals. The charge stored in the capacitor (990 uF @ 338 VDC) is available between the positive and “COM” terminals for the trip coil operation. The half wave rectification circuitry provides the advantage of maintaining a common neutral connection from the input and output while still maintaining the charge in the trip capacitor after a loss of control power. The capacitor is continuously charged when control power is applied. This provides energy for normal trip coil operation. Because mechanical relays are not used, energy from the trip coil operation is immediately available with the loss of control power. When the control power returns, the capacitor will recharge and will be able to supply energy for the next trip coil operation.  The CTD 5-120 manufactured by Electromagnetic Industries is designed to provide a source of energy for a circuit breaker or switch to trip during a loss of normal AC or DC power. The CTD-5 also has an alarm relay to continuously monitor the input and output of the device. This relay is energized when the proper input and output voltages are present. The relay changes state if the input voltage is lost, or the output voltage drops to 85%. An LED indicates normal operation.  These devices are protected against inadvertent short circuits, input from line surges and inductive kickback from trip coils. The nominal 120Volts AC is applied between “AC” and ‘COM” terminals. The charge stored in the capacitor (4500 uF @ 168 VDC) is available between the positive and “COM” terminals for the trip coil operation. The half wave rectification circuitry provides the advantage of maintaining a common neutral connection from the input and output while still maintaining the charge in the trip capacitor after a loss of control power. The capacitor is continuously charged when control power is applied. This provides energy for normal trip coil operation. Because mechanical relays are not used, energy from the trip coil operation is immediately available with the loss of control power. When the control power returns, the capacitor will recharge and will be able to supply energy for the next trip coil operation.  The CTD 5-240 manufactured by Electromagnetic Industries is designed to provide a source of energy for a circuit breaker or switch to trip during a loss of normal AC or DC power. The CTD-5 also has an alarm relay to continuously monitor the input and output of the device. This relay is energized when the proper input and output voltages are present. The relay changes state if the input voltage is lost, or the output voltage drops to 85%. An LED indicates normal operation. These devices are protected against inadvertent short circuits, input from line surges and inductive kickback from trip coils. The nominal 240Volts AC is applied between “AC” and ‘COM” terminals. The charge stored in the capacitor (990 uF @ 338 VDC) is available between the positive and “COM” terminals for the trip coil operation. The half wave rectification circuitry provides the advantage of maintaining a common neutral connection from the input and output while still maintaining the charge in the trip capacitor after a loss of control power. The capacitor is continuously charged when control power is applied. This provides energy for normal trip coil operation. Because mechanical relays are not used, energy from the trip coil operation is immediately available with the loss of control power. When the control power returns, the capacitor will recharge and will be able to supply energy for the next trip coil operation. Models available: CTD-1, CTD-2, CTD-3, CTD-4-120, CTD-4-240, CTD-5-120, CTD-5-240 Three Phase Voltage Monitor, Voltage Relays, Model EI SPVR  The SPVR (Three Phase Voltage Monitor) manufactured by Electromagnetic Industries is designed to protect electrical equipment from Phase Loss, Phase Unbalance, Phase Reversal, Under voltage and Overvoltage conditions.  A correctly installed SPVR (Three Phase Voltage Monitor) Voltage Sensing Relay will protect from Phase Loss, Phase Unbalance, Phase Reversal, Under voltage and Overvoltage conditions. The SPVR has an adjustable time delay for the trip as well as for the reset. It also has an adjustment for the Phase Unbalance (from 2% to 8%). The Phase Reversal is an instantaneous trip regardless of what the time delay is set for. The SPVR will hold in memory the condition that tripped the unit even after a power loss. The trip can be identified by pressing the “FAULT INDICATION” pushbutton up to 7 days after the fault. The SPVR will automatically reset at power up. Models available are: SPVR, SPVR-120, SPVR-208, SPVR-240, SPVR-308, SPVR-415, SPVR-480, SPVR-575  OCP OPEN CURCUIT PROTECTORS  1-OCP, 1-OCP-100, 1-OCP-200, 1-OCP-400, 3-OCP, 3-OCP-100, 3-OCP-200, 3-OCP-400 A Current Transformer secondary should never be open circuited while the Current Transformer primary circuit is energized. If this situation should occur there is a possibility of developing extremely high voltages which could be dangerous to personnel or cause an insulation breakdown. The 1-OCP series of Open Circuit Protectors manufactured by Electromagnetic Industries LLP. are voltage sensing devices using high speed shorting SCR switches. When the secondary peak voltage exceeds the clamping voltage value, the SCR operates, shorting the C.T. secondary and reducing the voltage to about 2 volts in less than 1/4 cycle. This process repeats each current polarity reversal. The protection is activated each half cycle.  The single element Open Circuit Protector is provided with two terminals for connection across the secondary of the C.T’s and in parallel with the burden. It can also be connected across the current terminals of a protective relay, meter or other current operated device without affecting the operation of the device. Secondary polarity of the C.T.’s is not critical to the OCP. The OCP also provides protection against high secondary voltage transients, which may damage the burden or secondary winding. If the transient voltage exceeds the voltage clamping limit, the Open Circuit Protector will trigger. After triggering, the voltage will fall to about 2 volts and remain there until the next zero crossing of the current waveform at which time the device resets and the cycle repeats as necessary. In the transient mode of protection, triggering will occur only on the half cycle where the transient appears. The leakage current of the OCP is insignificant and will not cause a ratio or phase angle error in the Current Transformer accuracy. Metering class C.T.’s with a rating factor of 2 could operate up to 10 amps on a continuous basis. The OCP is designed to tolerate both this condition and (80 amp RMS) for 2 seconds. 1-OCP A Current Transformer secondary should never be open circuited while the Current Transformer primary circuit is energized. If this situation should occur there is a possibility of developing extremely high voltages which could be dangerous to personnel or cause an insulation breakdown. The 3-OCP series of Open Circuit Protectors manufactured by Electromagnetic Industries LLP. are voltage sensing devices using high speed shorting SCR switches. When the secondary peak voltage exceeds the clamping voltage value, the SCR operates, shorting the C.T. secondary and reducing the voltage to about 2 volts in less than 1/4 cycle. This process repeats each current polarity reversal. The protection is activated each half cycle.  The three element Open Circuit Protector is provided with two terminals (for each phase or circuit) for connection across the secondary of the C.T’s and in parallel with the burden. It can also be connected across the current terminals of a protective relay, meter or other current operated device without affecting the operation of the device. Secondary polarity of the C.T.’s is not critical to the OCP. The OCP also provides protection against high secondary voltage transients, which may damage the burden or secondary winding. If the transient voltage exceeds the voltage clamping limit, the Open Circuit Protector will trigger. After triggering, the voltage will fall to about 2 volts and remain there until the next zero crossing of the current waveform at which time the device resets and the cycle repeats as necessary. In the transient mode of protection, triggering will occur only on the half cycle where the transient appears. The leakage current of the OCP is insignificant and will not cause a ratio or phase angle error in the Current Transformer accuracy. Metering class C.T.’s with a rating factor of 2 could operate up to 10 amps on a continuous basis. The OCP is designed to tolerate both this condition and (80 amp RMS) for 2 seconds. The OCP (Open Circuit Protector) manufactured by Electromagnetic Industries comes in two configurations, single and three phase and three voltage levels, 100, 200 and 400 VAC. Some of our current transformer models include the Model 2 CT, Model 2DT, Model 5 CT, Model 5 DRL, Model 6 CT, Model 7 CT, Model 8 CT, Model 19 CT, Model 125 and Model 170. There are other models also available. Please contact us with any questions or requests. Ground Fault Relays: Model BGFL, Model BGFL 137, Model BGFL 137-1, Model BGFL 137-2, Model BGFL 137-3, Model BGFL 137-60, Model BGFL 137-1200, Model BGFL 137-360, Model BGFL 147, Model BGFL 147-1, Model BGFL 147-2, Model BGFL 147-3, Model BGFL 147-60, Model BGFL 147-1200, Model BGFL 147-360, Model BGFL 157, Model BGFL 157-1, Model BGFL 157-2, Model BGFL 157-3, Model BGFL 157-60, Model BGFL 157-1200, Model BGFL 157-360, Model BGFL 139, Model BGFL 139-1, Model BGFL 139-2, Model BGFL 139-3, Model BGFL 139-60, Model BGFL 139-1200, Model BGFL 139-360, Model BGFL 259, Model BGFL 259-1, Model BGFL 259-2, Model BGFL 259-3, Model BGFL 259-60, Model BGFL 259-1200, Model BGFL 259-360, Model BGFL 159, Model BGFL 159-1, Model BGFL 159-2, Model BGFL 159-3, Model BGFL 159-60, Model BGFL 159-1200, Model BGFL 159-360, Model BGFL 237, Model BGFL 237-1, Model BGFL 237-2, Model BGFL 237-3, Model BGFL 237-60, BGFL 237-1200, BGFL 237-360, BGFL 247, BGFL 247-1, BGFL 247-2, BGFL 247-3, BGFL 247-60, BGFL 247-1200, Model BGFL 247-360, Model BGFL 257, Model BGFL 257-1, Model BGFL 257-2, Model BGFL 257-3, Model BGFL 257-60, Model BGFL 257-1200, Model BGFL 257-360, Model BGFL 239, Model BGFL 239-1, Model BGFL 239-2, Model BGFL 239-3, Model BGFL 239-60, Model BGFL 239-1200, Model BGFL 239-360, Model BGFL 249, Model BGFL 249-1, Model BGFL 249-2, Model BGFL 249-3, Model BGFL 249-60, Model BGFL 249-1200, Model BGFL 249-360, Model BGFL 259, Model BGFL 259-1, Model BGFL 259-2, Model BGFL 259-3, Model BGFL 259-60, Model BGFL 259-1200, Model BGFL 259-360 Ground Fault Relays: Model GFP, Model GFP 111-60, Model GFP 111-360, Model GFP 111-1200, Model GFP 111-60A, Model GFP 111-360A, Model GFP 111-1200A, Model GFP 111-60B, Model GFP 111-360B, Model GFP 111-1200B, Model GFP 112-60, Model GFP 112-360, Model GFP 112-1200, Model GFP 112-60A, Model GFP 112-360A, Model GFP 112-1200A, Model GFP 112-60B, Model GFP 112-360B, Model GFP 112-1200B, Model GFP 113-60, Model GFP 113-360, Model GFP 113-1200, Model GFP 113-60A, Model GFP 113-360A, Model GFP 113-1200A, Model GFP 113-60B, Model GFP 113-360B, Model GFP 113-1200B, Model GFP 121-60, Model GFP 121-360, Model GFP 121-1200, Model GFP 121-60A, Model GFP 121-360A, Model GFP 121-1200A, Model GFP 121-60B, Model GFP 121-360B, Model GFP 121-1200B, Model GFP 122-60, Model GFP 122-360, Model GFP 122-1200, Model GFP 122-60A, Model GFP 122-360A, Model GFP 122-1200A, Model GFP 122-60B, Model GFP 122-360B, Model GFP 122-1200B, Model GFP 123-60, Model GFP 123-360, Model GFP 123-1200, Model  GFP 123-60A, Model GFP 123-360A, Model GFP 123-1200A, Model GFP 123-60B, Model GFP 123-360B, Model GFP 123-1200B, Model GFP 131-60, Model GFP 131-360, Model GFP 131-1200, Model GFP 131-60A, Model GFP 131-360A, Model GFP 131-1200A, Model GFP 131-60B, Model GFP 131-360B, Model GFP 131-1200B, Model GFP 132-60, Model GFP 132-360, Model GFP 132-1200, Model GFP 132-60A, Model GFP 132-360A, Model GFP 132-1200A, Model GFP 132-60B, Model GFP 132-360B, Model GFP 132-1200B, Model GFP 133-60, GFP 133-360, Model GFP 133-1200, Model GFP 133-60A, Model GFP 133-360A, Model GFP 133-1200A, Model GFP 133-60B, Model GFP 133-360B, Model GFP 133-1200B, Model GFP 141-60, Model GFP 141-360, Model GFP 141-1200, Model GFP 141-60A, Model GFP 141-360A, Model GFP 141-1200A, Model GFP 141-60B, Model GFP 141-360B, Model GFP 141-1200B, Model GFP 142-60, Model GFP 142-360, Model GFP 142-1200, Model GFP 142-60A, Model GFP 142-360A, Model GFP 142-1200A, Model GFP 142-60B, GFP 142-360B, GFP 142-1200B, GFP 143-60, GFP 143-360, GFP 143-1200,  GFP 143-60A, GFP 143-360A, GFP 143-1200A, Model GFP 143-60B, Model GFP 143-360B, Model GFP 143-1200B, Model GFP 211-60, Model GFP 211-360, Model GFP 211-1200, Model GFP 211-60A, Model GFP 211-360A, Model GFP 211-1200A, Model GFP 211-60B, Model GFP 211-360B, Model GFP 211-1200B, Model GFP 212-60, Model GFP 212-360, Model GFP 212-1200, Model GFP 212-60A, Model GFP 212-360A, Model GFP 212-1200A, Model GFP 212-60B, Model GFP 212-360B, Model GFP 212-1200B, Model GFP 213-60, Model GFP 213-360, Model GFP 213-1200, Model GFP 213-60A, Model GFP 213-360A, Model GFP 213-1200A, Model GFP 213-60B, Model GFP 213-360B, Model GFP 213-1200B, Model GFP 221-60, Model GFP 221-360, Model GFP 221-1200, Model GFP 221-60A, Model GFP 221-360A, Model GFP 221-1200A, Model GFP 221-60B, Model GFP 221-360B, Model GFP 221-1200B, Model GFP 222-60, Model GFP 222-360, Model GFP 222-1200, Model GFP 222-60A, Model GFP 222-360A, Model GFP 222-1200A, Model GFP 222-60B, Model GFP 222-360B, Model GFP 222-1200B, Model GFP 223-60, Model GFP 223-360, Model GFP 223-1200, Model GFP 223-60A, Model GFP 223-360A, Model GFP 223-1200A, Model GFP 223-60B, Model GFP 223-360B, Model GFP 223-1200B, Model GFP 231-60, Model GFP 231-360, Model GFP 231-1200, Model GFP 231-60A, Model GFP 231-360A, Model GFP 231-1200A, Model GFP 231-60B, Model GFP 231-360B, Model GFP 231-1200B, Model GFP 232-60, Model GFP 232-360, Model GFP 232-1200, Model GFP 232-60A, Model GFP 232-360A, Model GFP 232-1200A, Model GFP 232-60B, Model GFP 232-360B, Model GFP 232-1200B, Model GFP 233-60, Model GFP 233-360, Model GFP 233-1200, Model GFP 233-60A, Model GFP 233-360A, Model GFP 233-1200A, Model GFP 233-60B, Model GFP 233-360B, Model GFP 233-1200B, Model GFP 241-60, GFP 241-360, Model GFP 241-1200, Model GFP 241-60A, Model GFP 241-360A, Model GFP 241-1200A, Model GFP 241-60B, GFP 241-360B, GFP 241-1200B, GFP 242-60, GFP 242-360, GFP 242-1200,  GFP 242-60A, GFP 242-360A, GFP 242-1200A, Model GFP 242-60B, Model GFP 242-360B, Model GFP 242-1200B, Model GFP 243-60, Model GFP 243-360, Model GFP 243-1200, Model GFP 243-60A, Model GFP 243-360A, Model GFP 243-1200A, Model GFP 243-60B, Model GFP 243-360B, Model GFP 243-1200B, Ground Fault Relay: Model GFM, Model GFM 252, Model GFM 262, Model GFM 352, Model GFM 362, Model GFM 452, Model GFM 462, Model GFM 041X071, Model GFM 080X141, Model GFM 080X117SC, Model GFM 094, Model GFM 125, Model GFM 156, Model GFM 200, Model GFM 250, Model GFM 375, Model GFM 375D, Model GFM 425, Model GFM 465, Model GFM 813, Capacitor Trip Devices: Model CTD, Model CTD-1, Model CTD-2, Model CTD-3, Model CTD-4 120, Model CTD-4 240, Model CTD-5 120, Model CTD-5 240, Model CTD 1, Model CTD 2, Model CTD 3, Model CTD 4-120, Model CTD 4-240, Model CTD 5-120, Model CTD 5-240, Three Phase Voltage Monitor, Three Phase Voltage Relay: Model SPVR, Model EI SPVR, Model SPVR 208, Model SPVR 240, Model SPVR 380, Model SPVR 415, Model SPVR 480 Model, Model SPVR 575, Model SPVR-208, Model SPVR-240, Model SPVR-380, Model SPVR-415, Model SPVR-480, Model SPVR-575, Model EI SPVR 208, Model EI SPVR 240, Model EI SPVR 380, Model EI SPVR 415, Model EI SPVR 480, Model EI SPVR 575, Model EI SPVR-208, Model EI SPVR-240, Model EI SPVR-380, Model EI SPVR-415, Model EI SPVR-480, Model EI SPVR-575, Model SPVR 208-D, Model SPVR 240-D, Model SPVR 380-D, Model SPVR 415-D, Model SPVR 480-D, Model SPVR 575-D, Model SPVR-208-D, Model SPVR-240-D, Model SPVR-380-D, Model SPVR-415-D, Model SPVR-480-D, Model SPVR-575-D, Model EI SPVR 208-D, Model EI SPVR 240-D, Model EI SPVR 380-D, Model EI SPVR 415-D, Model EI SPVR 480-D, Model EI SPVR 575-D, Model EI SPVR-208-D, Model EI SPVR-240-D, Model EI SPVR-380-D, Model EI SPVR-415-D, Model EI SPVR-480-D, Model EI SPVR-575-D, Open Circuit Protector: Model OCP, Model 1-OCP-100, Model 1-OCP-200, Model 1-OCP-300, Model 3-OCP-100, Model 3-OCP-200, Model 3- OCP-400, Model 1 OCP-100, Model 1 OCP-200, Model 1 OCP-300, Model 3 OCP-100, Model 3 OCP-200, Model 3 OCP-400, Model 460 Voltage Transformers, Models available: Model 460-069, Model 460-120, Model 460-208, Model 460-277, Model 460-288, Model 460-300, Model 460-346, Model 460-480, Model 460-600, See datasheet for details. Model 467 Voltage Transformers, Models available: Model 467-069, Model 467-120, Model 467-208, Model 467-277, Model 467-288, Model 467-300, Model 467-346, Model 467-480, Model 467-600, See datasheet for details. Model 468 Voltage Transformers, Models available: Model 468-069, Model 468-120, Model 468-208, Model 468-277, Model 468-288, Model 468-300, Model 468-346, Model 468-480, Model 468-600, See datasheet for details. Model 2VT 469 Voltage Transformers, Models available: Model 2VT 469-069, Model 2VT 469-120, Model 2VT 469-208, Model 2VT 469-277, Model 2VT 469-288, Model 2VT 469-300, Model 2VT 469-346, Model 2VT 469-480, Model 2VT 469-600, See datasheet for details. Model 2 Instrument Transformers, Model 2RL, Model 2RL 500, Model 2RL 600, Model 2RL 750, Model 2RL 800, Model 2RL 101, Model 2RL 121, Model 2RL 1250, Model 2RL 151, Model 2RL 201, Model 2RL 251, Model 2RL 301, Model 2RL 401, Model 2SHT, Model 2SHT 500, Model 2SHT 600, Model 2SHT 750, Model 2SHT 800, Model 2SHT 101, Model 2SHT 121, Model 2SHT 1250, Model 2SHT 151, Model 2SHT 201, Model 2SHT 251, Model 2SHT 301, Model 2SHT 401, Model 2SHL, Model 2SHL 500, Model 2SHL 600, Model 2SHL 750, Model 2SHL 800, Model 2SHL 101, Model 2SHL 121, Model 2SHL 1250, Model 2SHL 151, Model 2SHL 201, Model 2SHL 251, Model 2SHL 301, Model 2SHL 401, Model 2SFT, Model 2SFT 500, Model 2SFT 600, Model 2SFT 750, Model 2SFT 800, Model 2SFT 101, Model 2SFT 121, Model 2SFT 1250, Model 2SFT 151, Model 2SFT 201, Model 2SFT 251, Model 2SFT 301, Model 2SFT 401, Model 2SFL, Model 2SFL 500, Model 2SFL 600, Model 2SFL 750, Model 2SFL 800, Model 2SFL 101, Model 2SFL 121, Model 2SFL 1250, Model 2SFL 151, Model 2SFL 201, Model 2SFL 251, Model 2SFL 301, Model 2SFL 401, Model 2DRL, Model 2DRL 500, Model 2DRL 600, Model 2DRL 750, Model 2DRL 800, Model 2DRL 101, Model 2DRL 121, Model 2DRL 1250, Model 2DRL 151, Model 2DRL 201, Model 2DRL 251, Model 2DRL 301, Model 2DRL 401, Model 2 Instrument Transformers, Model 2RL, Model 2RL-500, Model 2RL-600, Model 2RL-750, Model 2RL-800, Model 2RL -101, Model 2RL-121, Model 2RL-1250, Model 2RL-151, Model 2RL-201, Model 2RL-251, Model 2RL-301, Model 2RL-401, Model 2SHT, Model 2SHT-500, Model 2SHT-600, Model 2SHT-750, Model 2SHT-800, Model 2SHT-101, Model 2SHT-121, Model 2SHT 1250, Model 2SHT 151, Model 2SHT 201, Model 2SHT 251, Model 2SHT 301, Model 2SHT 401, Model 2SHL, Model 2SHL-500, Model 2SHL-600, Model 2SHL-750, Model 2SHL-800, Model 2SHL-101, Model 2SHL-121, Model 2SHL-1250, Model 2SHL-151, Model 2SHL-201, Model 2SHL-251, Model 2SHL-301, Model 2SHL-401, Model 2SFT, Model 2SFT-500, Model 2SFT-600, Model 2SFT-750, Model 2SFT-800, Model 2SFT-101, Model 2SFT-121, Model 2SFT-1250, Model 2SFT-151, Model 2SFT-201, Model 2SFT-251, Model 2SFT-301, Model 2SFT-401, Model 2SFL, Model 2SFL-500, Model 2SFL-600, Model 2SFL- 750, Model 2SFL-800, Model 2SFL-101, Model 2SFL-121, Model 2SFL-1250, Model 2SFL-151, Model 2SFL-201, Model 2SFL-251, Model 2SFL-301, Model 2SFL-401, Model 2DRL, Model 2DRL-500, Model 2DRL-600, Model 2DRL-750, Model 2DRL-800, Model 2DRL-101, Model 2DRL-121, Model 2DRL-1250, Model 2DRL-151, Model 2DRL-201, Model 2DRL-251, Model 2DRL-301, Model 2DRL-401, Model 5 Instrument Transformers, Model 5RL, Model 5RL 500, Model 5RL 600, Model 5RL 750, Model 5RL 800, Model 5RL 101, Model 5RL 121, Model 5RL 1250, Model 5RL 151, Model 5RL 201, Model 5RL 251, Model 5RL 301, Model 5RL 401, Model 5RL 501. Model 5RL 601, Model 5RL 750, Model 5RL 801, Model 5RL 102, Model 5RL 122, Model 5SFT, Model 5SFT 500, Model 5SFT 600, Model 5SFT 750, Model 5SFT 800, Model 5SFT 101, Model 5SFT 121, Model 5SFT 1250, Model 5SFT 151, Model 5SFT 201, Model 5SFT 251, Model 5SFT 301, Model 5SFT 401, Model 5SFT 501. Model 5SFT 601, Model 5SFT 750, Model 5SFT 801, Model 5SFT 102, Model 5SFT 122,Model 5SFL, Model 5SFL 500, Model 5SFL 600, Model 5SFL 750, Model 5SFL 800, Model 5SFL 101, Model 5SFL 121, Model 5SFL 1250, Model 5SFL 151, Model 5SFL 201, Model 5SFL 251, Model 5SFL 301, Model 5SFL 401, Model 5SFL 501. Model 5SFL 601, Model 5SFL 750, Model 5SFL 801, Model 5SFL 102, Model 5SFL 122, Model 5SHT, Model 5SHT 500, Model 5SHT 600, Model 5SHT 750, Model 5SHT 800, Model 5SHT 101, Model 5SHT 121, Model 5SHT 1250, Model 5SHT 151, Model 5SHT 201, Model 5SHT 251, Model 5SHT 301, Model 5SHT 401, Model 5SHT 501. Model 5SHT 601, Model 5SHT 750, Model 5SHT 801, Model 5SHT 102, Model 5SHT 122, Model 5SHL, Model 5SHL 500, Model 5SHL 600, Model 5SHL 750, Model 5SHL 800, Model 5SHL 101, Model 5SHL 121, Model 5SHL 1250, Model 5SHL151, Model 5SHL 201, Model 5SHL 251, Model 5SHL 301, Model 5SHL 401, Model 5SHL 501. Model 5SHL 601, Model 5SHL 750, Model 5SHL 801, Model 5SHL 102, Model 5SHL 122, Model 6 Instrument Transformers, Model 6RL, Model 6RL-101, Model 6RL-121, Model 6RL-151, Model 6RL-201, Model 6RL- 251, Model 6RL-301, Model 6RL-401, Model 6RL-501. Model 6RL-601, Model 6RL-750, Model 6RL-801, Model 6RL-102, Model 6RL-122, Model 6RL-152, Model 6SFT, Model 6SFT-101, Model 6SFT-121, Model 6SFT-151, Model 6SFT-201, Model 6SFT- 251, Model 6SFT-301, Model 6SFT-401, Model 6SFT-501. Model 6SFT-601, Model 6SFT-750, Model 6SFT-801, Model 6SFT-102, Model 6SFT-122, Model 6SFT-152, Model 6SHT, Model 6SHT-101, Model 6SHT-121, Model 6SHT-151, Model 6SHT-201, Model 6SHT-251, Model 6SHT-301, Model 6SHT-401, Model 6SHT-501. Model 6SHT-601, Model 6SHT-750, Model 6SHT-801, Model 6SHT-102, Model 6SHT-122, Model 6SHT-152, Model 6SFL, Model 6SFL-101, Model 6SFL-121, Model 6SFL-151, Model 6SFL-201, Model 6SFL-251, Model 6SFL-301, Model 6SFL-401, Model 6SFL-501. Model 6SFL-601, Model 6SFL-750, Model 6SFL-801, Model 6SFL-102, Model 6SFL-122, Model 6SFL-152, Model 6SHL, Model 6SHL-101, Model 6SHL-121, Model 6SHL-151, Model 6SHL-201, Model 6SFL-251, Model 6SHL-301, Model 6SHL-401, Model 6SHL-501. Model 6SHL-601, Model 6SHL-750, Model 6SHL-801, Model 6SHL-102, Model 6SHL-122, Model 6SHL-152, Model 6RL, Model 6RL 101, Model 6RL 121, Model 6RL 151, Model 6RL 201, Model 6RL 251, Model 6RL 301, Model 6RL 401, Model 6RL 501. Model 6RL 601, Model 6RL 750, Model 6RL 801, Model 6RL 102, Model 6RL 122, Model 6RL 152, Model 6SFT, Model 6SFT 101, Model 6SFT 121, Model 6SFT 151, Model 6SFT 201, Model 6SFT 251, Model 6SFT 301, Model 6SFT 401, Model 6SFT 501. Model 6SFT 601, Model 6SFT 750, Model 6SFT 801, Model 6SFT 102, Model 6SFT 122, Model 6SFT 152, Model 6SHT, Model 6SHT 101, Model 6SHT 121, Model 6SHT 151, Model 6SHT 201, Model 6SHT 251, Model 6SHT 301, Model 6SHT 401, Model 6SHT 501. Model 6SHT 601, Model 6SHT 750, Model 6SHT 801, Model 6SHT 102, Model 6SHT 122, Model 6SHT 152, Model 6SFL, Model 6SFL 101, Model 6SFL 121, Model 6SFL 151, Model 6SFL 201, Model 6SFL-251, Model 6SFL 301, Model 6SFL 401, Model 6SFL 501. Model 6SFL 601, Model 6SFL 750, Model 6SFL 801, Model 6SFL 102, Model 6SFL 122, Model 6SFL 152, Model 6SHL, Model 6SHL 101, Model 6SHL 121, Model 6SHL 151, Model 6SHL 201, Model 6SFL-251, Model 6SHL 301, Model 6SHL 401, Model 6SHL 501, Model 6SHL 601, Model 6SHL 750, Model 6SHL 801, Model 6SHL 102, Model 6SHL 122, Model 6SHL 152, Model 7 Instrument Transformers, Model 7RL, Model 7RL-101, Model 7RL-121, Model 7RL-151, Model 7RL-201, Model 7RL- 251, Model 7RL-301, Model 7RL-401, Model 7RL-501. Model 7RL-601, Model 7RL-750, Model 7RL-801, Model 7RL-102, Model 7RL-122, Model 7RL-152, Model 7RL-162 Model 7SFT, Model 7SFT-101, Model 7SFT-121, Model 7SFT-151, Model 7SFT-201, Model 7SFT- 251, Model 7SFT-301, Model 7SFT-401, Model 7SFT-501. Model 7SFT-601, Model 7SFT-750, Model 7SFT-801, Model 7SFT-102, Model 7SFT-122, Model 7SFT-152, Model 7SFT-162, Model 7SHT, Model 7SHT-101, Model 7SHT-121, Model 7SHT-151, Model 7SHT-201, Model 7SHT-251, Model 7SHT-301, Model 7SHT-401, Model 7SHT-501. Model 7SHT-601, Model 7SHT-750, Model 7SHT-801, Model 7SHT-102, Model 7SHT-122, Model 7SHT-152, Model 7SHT-162,  Model 7SFL, Model 7SFL-101, Model 7SFL-121, Model 7SFL-151, Model 7SFL-201, Model 7SFL-251, Model 7SFL-301, Model 7SFL-401, Model 7SFL-501. Model 7SFL-601, Model 7SFL-750, Model 7SFL-801, Model 7SFL-102, Model 7SFL-122, Model 7SFL-152, Model 7SFL-162,  Model 7SHL, Model 7SHL-101, Model 7SHL-121, Model 7SHL-151, Model 7SHL-201, Model 7SFL-251, Model 7SHL-301, Model 7SHL-401, Model 7SHL-501. Model 7SHL-601, Model 7SHL-750, Model 7SHL-801, Model 7SHL-102, Model 7SHL-122, Model 7SHL-152, Model 7SHL-162, Model 7RL, Model 7RL 101, Model 7RL 121, Model 7RL 151, Model 7RL 201, Model 7RL 251, Model 7RL 301, Model 7RL 401, Model 7RL 501. Model 7RL 601, Model 7RL 750, Model 7RL 801, Model 7RL 102, Model 7RL 122, Model 7RL 152, Model 7RL 162,  Model 7SFT, Model 7SFT 101, Model 7SFT 121, Model 7SFT 151, Model 7SFT 201, Model 7SFT 251, Model 7SFT 301, Model 7SFT 401, Model 7SFT 501. Model 7SFT 601, Model 7SFT 750, Model 7SFT 801, Model 7SFT 102, Model 7SFT 122, Model 7SFT 152, Model 7SFT 162, Model 7SHT, Model 7SHT 101, Model 7SHT 121, Model 7SHT 151, Model 7SHT 201, Model 7SHT 251, Model 7SHT 301, Model 7SHT 401, Model 7SHT 501. Model 7SHT 601, Model 7SHT 750, Model 7SHT 801, Model 7SHT 102, Model 7SHT 122, Model 7SHT 152, Model 7SHT 162,  Model 7SFL, Model 7SFL 101, Model 7SFL 121, Model 7SFL 151, Model 7SFL 201, Model 7SFL-251, Model 7SFL 301, Model 7SFL 401, Model 7SFL 501. Model 7SFL 601, Model 7SFL 750, Model 7SFL 801, Model 7SFL 102, Model 7SFL 122, Model 7SFL 152, Model 7SFL 162, Model 7SHL, Model 7SHL 101, Model 7SHL 121, Model 7SHL 151, Model 7SHL 201, Model 7SFL-251, Model 7SHL 301, Model 7SHL 401, Model 7SHL 501, Model 7SHL 601, Model 7SHL 750, Model 7SHL 801, Model 7SHL 102, Model 7SHL 122, Model 7SHL 152, Model 7SHL 162, Ground Fault Sensors: Model GFL 041, Model GFL 041X071-1, Model 041X117-1, Model 041X141-1, Model 041X181-1, Model 041X240-1, Model 041X301-1, Model 041X360-1, Model GFL 041X071-2, Model 041X117-2, Model 041X141-2, Model 041X181-2, Model 041X240-2, Model 041X301-2, Model 041X360-2, Model GFL 041X071-3, Model 041X117-3, Model 041X141-3, Model 041X181-3, Model 041X240-3, Model 041X301-3, Model 041X360-3, Model GFL 041X071-60, Model 041X117-60, Model 041X141-60, Model 041X181-60, Model 041X240-60, Model 041X301-60, Model 041X360-60, Model GFL 041X071-360, Model 041X117-360, Model 041X141-360, Model 041X181-360, Model 041X240-360, Model 041X301-360, Model 041X360-360, Model GFL 041X071-1200, Model 041X117-1200, Model 041X141-1200, Model 041X181-1200, Model 041X240-1200, Model 041X301-1200, Model 041X360-1200, Split Core, Ground Fault Sensors: Model GFL, Model GFL 041X071-SC-1, Model 041X117-SC-1, Model 041X141-SC-1, Model 041X181-SC-1, Model 041X240-SC-1, Model 041X301-SC-1, Model 041X360-SC-1, Model GFL 041X071-SC-2, Model 041X117-SC-2, Model 041X141-SC-2, Model 041X181-SC-2, Model 041X240-SC-2, Model 041X301-SC-2, Model 041X360-SC-2, Model GFL 041X071-SC-3, Model 041X117-SC-3, Model 041X141-SC-3, Model 041X181-SC-3, Model 041X240-SC-3, Model 041X301-SC-3, Model 041X360-SC-3, Model GFL 041X071-SC-60, Model 041X117-SC-60, Model 041X141-SC-60, Model 041X181-SC-60, Model 041X240-SC-60, Model 041X301-SC-60, Model 041X360-SC-60, Model GFL 041X071-SC-360, Model 041X117-SC-360, Model 041X141-SC-360, Model 041X181-SC-360, Model 041X240-SC-360, Model 041X301-SC-360, Model 041X360-SC-360, Model GFL 041X071-SC-1200, Model 041X117-SC-1200, Model 041X141-SC-1200, Model 041X181-SC-1200, Model 041X240-SC-1200, Model 041X301-SC-1200, Model 041X360-SC-1200, Ground Fault Sensors: Model GFL 051, Model GFL 051X071-1, Model 051X117-1, Model 051X141-1, Model 051X181-1, Model 051X240-1, Model 051X301-1, Model 051X360-1, Model GFL 051X071-2, Model 051X117-2, Model 051X141-2, Model 051X181-2, Model 051X240-2, Model 051X301-2, Model 051X360-2, Model GFL 051X071-3, Model 051X117-3, Model 051X141-3, Model 051X181-3, Model 051X240-3, Model 051X301-3, Model 051X360-3, Model GFL 051X071-60, Model 051X117-60, Model 051X141-60, Model 051X181-60, Model 051X240-60, Model 051X301-60, Model 051X360-60, Model GFL 051X071-360, Model 051X117-360, Model 051X141-360, Model 051X181-360, Model 051X240-360, Model 051X301-360, Model 051X360-360, Model GFL 051X071-1200, Model 051X117-1200, Model 051X141-1200, Model 051X181-1200, Model 051X240-1200, Model 051X301-1200, Model 051X360-1200, Split Core, Ground Fault Sensors: Model GFL, Model GFL 051X071-SC-1, Model 051X117-SC-1, Model 051X141-SC-1, Model 051X181-SC-1, Model 051X240-SC-1, Model 051X301-SC-1, Model 051X360-SC-1, Model GFL 051X071-SC-2, Model 051X117-SC-2, Model 051X141-SC-2, Model 051X181-SC-2, Model 051X240-SC-2, Model 051X301-SC-2, Model 051X360-SC-2, Model GFL 051X071-SC-3, Model 051X117-SC-3, Model 051X141-SC-3, Model 051X181-SC-3, Model 051X240-SC-3, Model 051X301-SC-3, Model 051X360-SC-3, Model GFL 051X071-SC-60, Model 051X117-SC-60, Model 051X141-SC-60, Model 051X181-SC-60, Model 051X240-SC-60, Model 051X301-SC-60, Model 051X360-SC-60, Model GFL 051X071-SC-360, Model 051X117-SC-360, Model 051X141-SC-360, Model 051X181-SC-360, Model 051X240-SC-360, Model 051X301-SC-360, Model 051X360-SC-360, Model GFL 051X071-SC-1200, Model 051X117-SC-1200, Model 051X141-SC-1200, Model 051X181-SC-1200, Model 051X240-SC-1200, Model 051X301-SC-1200, Model 051X360-SC-1200, Ground Fault Sensors: Model GFL 058, Model GFL 058X071-1, Model 058X117-1, Model 058X141-1, Model 058X181-1, Model 058X240-1, Model 058X301-1, Model 058X360-1, Model GFL 058X071-2, Model 058X117-2, Model 058X141-2, Model 058X181-2, Model 058X240-2, Model 058X301-2, Model 058X360-2, Model GFL 058X071-3, Model 058X117-3, Model 058X141-3, Model 058X181-3, Model 058X240-3, Model 058X301-3, Model 058X360-3, Model GFL 058X071-60, Model 058X117-60, Model 058X141-60, Model 058X181-60, Model 058X240-60, Model 058X301-60, Model 058X360-60, Model GFL 058X071-360, Model 058X117-360, Model 058X141-360, Model 058X181-360, Model 058X240-360, Model 058X301-360, Model 058X360-360, Model GFL 058X071-1200, Model 058X117-1200, Model 058X141-1200, Model 058X181-1200, Model 058X240-1200, Model 058X301-1200, Model 058X360-1200, Split Core, Ground Fault Sensors: Model GFL, Model GFL 058X071-SC-1, Model 058X117-SC-1, Model 058X141-SC-1, Model 058X181-SC-1, Model 058X240-SC-1, Model 058X301-SC-1, Model 058X360-SC-1, Model GFL 058X071-SC-2, Model 058X117-SC-2, Model 058X141-SC-2, Model 058X181-SC-2, Model 058X240-SC-2, Model 058X301-SC-2, Model 058X360-SC-2, Model GFL 058X071-SC-3, Model 058X117-SC-3, Model 058X141-SC-3, Model 058X181-SC-3, Model 058X240-SC-3, Model 058X301-SC-3, Model 058X360-SC-3, Model GFL 058X071-SC-60, Model 058X117-SC-60, Model 058X141-SC-60, Model 058X181-SC-60, Model 058X240-SC-60, Model 058X301-SC-60, Model 058X360-SC-60, Model GFL 058X071-SC-360, Model 058X117-SC-360, Model 058X141-SC-360, Model 058X181-SC-360, Model 058X240-SC-360, Model 058X301-SC-360, Model 058X360-SC-360, Model GFL 058X071-SC-1200, Model 058X117-SC-1200, Model 058X141-SC-1200, Model 058X181-SC-1200, Model 058X240-SC-1200, Model 058X301-SC-1200, Model 058X360-SC-1200, Ground Fault Sensors: Model GFL 080, Model GFL 080X071-1, Model 080X117-1, Model 080X141-1, Model 080X181-1, Model 080X240-1, Model 080X301-1, Model 080X360-1, Model GFL 080X071-2, Model 080X117-2, Model 080X141-2, Model 080X181-2, Model 080X240-2, Model 080X301-2, Model 080X360-2, Model GFL 080X071-3, Model 080X117-3, Model 080X141-3, Model 080X181-3, Model 080X240-3, Model 080X301-3, Model 080X360-3, Model GFL 080X071-60, Model 080X117-60, Model 080X141-60, Model 080X181-60, Model 080X240-60, Model 080X301-60, Model 080X360-60, Model GFL 080X071-360, Model 080X117-360, Model 080X141-360, Model 080X181-360, Model 080X240-360, Model 080X301-360, Model 080X360-360, Model GFL 080X071-1200, Model 080X117-1200, Model 080X141-1200, Model 080X181-1200, Model 080X240-1200, Model 080X301-1200, Model 080X360-1200, Split Core, Ground Fault Sensors: Model GFL, Model GFL 080X071-SC-1, Model 080X117-SC-1, Model 080X141-SC-1, Model 080X181-SC-1, Model 080X240-SC-1, Model 080X301-SC-1, Model 080X360-SC-1, Model GFL 080X071-SC-2, Model 080X117-SC-2, Model 080X141-SC-2, Model 080X181-SC-2, Model 080X240-SC-2, Model 080X301-SC-2, Model 080X360-SC-2, Model GFL 080X071-SC-3, Model 080X117-SC-3, Model 080X141-SC-3, Model 080X181-SC-3, Model 080X240-SC-3, Model 080X301-SC-3, Model 080X360-SC-3, Model GFL 080X071-SC-60, Model 080X117-SC-60, Model 080X141-SC-60, Model 080X181-SC-60, Model 080X240-SC-60, Model 080X301-SC-60, Model 080X360-SC-60, Model GFL 080X071-SC-360, Model 080X117-SC-360, Model 080X141-SC-360, Model 080X181-SC-360, Model 080X240-SC-360, Model 080X301-SC-360, Model 080X360-SC-360, Model GFL 080X071-SC-1200, Model 080X117-SC-1200, Model 080X141-SC-1200, Model 080X181-SC-1200, Model 080X240-SC-1200, Model 080X301-SC-1200, Model 080X360-SC-1200, Ground Fault Sensors: Model GFL 101, Model GFL 101X071-1, Model 101X117-1, Model 101X141-1, Model 101X181-1, Model 101X240-1, Model 101X301-1, Model 101X360-1, Model GFL 101X071-2, Model 101X117-2, Model 101X141-2, Model 101X181-2, Model 101X240-2, Model 101X301-2, Model 101X360-2, Model GFL 101X071-3, Model 101X117-3, Model 101X141-3, Model 101X181-3, Model 101X240-3, Model 101X301-3, Model 101X360-3, Model GFL 101X071-60, Model 101X117-60, Model 101X141-60, Model 101X181-60, Model 101X240-60, Model 101X301-60, Model 101X360-60, Model GFL 101X071-360, Model 101X117-360, Model 101X141-360, Model 101X181-360, Model 101X240-360, Model 101X301-360, Model 101X360-360, Model GFL 101X071-1200, Model 101X117-1200, Model 101X141-1200, Model 101X181-1200, Model 101X240-1200, Model 101X301-1200, Model 101X360-1200, Split Core, Ground Fault Sensors: Model GFL, Model GFL 101X071-SC-1, Model 101X117-SC-1, Model 101X141-SC-1, Model 101X181-SC-1, Model 101X240-SC-1, Model 101X301-SC-1, Model 101X360-SC-1, Model GFL 101X071-SC-2, Model 101X117-SC-2, Model 101X141-SC-2, Model 101X181-SC-2, Model 101X240-SC-2, Model 101X301-SC-2, Model 101X360-SC-2, Model GFL 101X071-SC-3, Model 101X117-SC-3, Model 101X141-SC-3, Model 101X181-SC-3, Model 101X240-SC-3, Model 101X301-SC-3, Model 101X360-SC-3, Model GFL 101X071-SC-60, Model 101X117-SC-60, Model 101X141-SC-60, Model 101X181-SC-60, Model 101X240-SC-60, Model 101X301-SC-60, Model 101X360-SC-60, Model GFL 101X071-SC-360, Model 101X117-SC-360, Model 101X141-SC-360, Model 101X181-SC-360, Model 101X240-SC-360, Model 101X301-SC-360, Model 101X360-SC-360, Model GFL 101X071-SC-1200, Model 101X117-SC-1200, Model 101X141-SC-1200, Model 101X181-SC-1200, Model 101X240-SC-1200, Model 101X301-SC-1200, Model 101X360-SC-1200, Ground Fault Sensors: Model GFM, Model GFM 041X071, Model GFM 080X141, Model GFM 080X117SC, Model GFM 094, Model GFM 125, Model GFM 156, Model GFM 200, Model GFM 250, Model GFM 375, Model GFM 375D, Model GFM 425, Model GFM 465, Model GFM 813, Split Core Instrument Transformers, Take Apart Instrument Transformers, Model 500T Instrument Transformers, Model 500L Instrument Transformers, Model 550T Instrument Transformers, Model 550L Instrument Transformers, Model 600 Instrument Transformers, Model 601 Instrument Transformers. Model 500T Current Transformer, Current Instrument Transformer, Take Apart Current Transformers, Split Core Current Transformers, Model 500T 041x071-101, Model 500T 041x071-151, Model 500T

Privacy Statement  |  Terms Of Use
Copyright 2009 by Electromagnetic Industries